Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
West China Journal of Stomatology ; (6): 37-41, 2019.
Article in Chinese | WPRIM | ID: wpr-772703

ABSTRACT

OBJECTIVE@#This study aimed to compare the passive fits of implant-supported cement-retained computer aided design/computer aided manufacturing (CAD/CAM) bridges fabricated with different implant superstructure designs from zirconia and titanium.@*METHODS@#A total of 32 cubic clods with the same dimensions and with elastic modulus similar to that of mandibles were used. Each clod received two one-stage implants to simulate a partially edentulous jaw that was missing teeth between the lower left second premolar and second molar. Four linear strain gauges were bonded on the region surrounding each implant on the mesial, buccal, distal, and lingual aspects. A total of 32 identical frameworks were fabricated through CAD/CAM after scanning. The frameworks were allocated into four different groups (n=8) in accordance with material types and superstructure designs. Group A included zirconia ceramic implant-supported fixed prostheses with regular marginal designs. Group B comprised zirconia ceramic implant-supported fixed prostheses with full circumferential zirconia-collar marginal designs. Group C consisted of titanium ceramic implant-supported fixed prostheses with regular marginal designs. Group D included titanium ceramic implant-supported fixed prostheses with full circumferential titanium-collar marginal designs. Strain development before and after ceramic veneering was recorded during cement setting. Data were statistically analyzed by using SPSS software.@*RESULTS@#Before ceramic veneering, material types affected the strains of prostheses, and zirconia frameworks showed lower strain than other frameworks (P0.05). Nevertheless, the full circumferential collar marginal design reduced discrepancies among groups (P<0.01).@*CONCLUSIONS@#The passive fits of zirconia prostheses were better than those of titanium-based porcelain-fused-to-metal restorations. The full circumferential collar marginal design can help reduce fit inaccuracy, as well as the adverse effects of ceramic veneering.


Subject(s)
Computer-Aided Design , Dental Porcelain , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Titanium , Zirconium
2.
The Journal of Korean Academy of Prosthodontics ; : 53-60, 2017.
Article in Korean | WPRIM | ID: wpr-39477

ABSTRACT

When attempting to restore the oral function of a partially edentulous patient, there are a number of prosthetic treatment options available, depending on the structure of remaining teeth. For example, when only one set of maxillary and mandibular teeth are diagonally in place across from each other, it is difficult to gain stable occlusion. In this case, implants can be put in place at the corresponding edentulous area to achieve balance. By doing so, a stable occlusion can be achieved. For this case report, a patient with crossed occlusion after extraction was treated with maxillary RDP (removable dental prosthesis) and mandibular implant-supported RDP (removable dental prosthesis). Moreover, an implant fixture was placed under the posterior molar of the distal extension base diagonally across from the remaining maxillary teeth. Then, magnetic attachment was implemented. According to the patient who received the treatment, the result was functionally and aesthetically satisfactory.


Subject(s)
Humans , Dental Prosthesis , Molar , Tooth
3.
ImplantNewsPerio ; 1(8): 1514-1521, nov.-dez. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-848535

ABSTRACT

Objetivo: avaliar a desadaptação marginal vertical e interna entre o cilindro cimentável e o coping metálico de próteses sobre implantes com o uso de três diferentes tipos de cimentos: um provisório, o cimento de hidróxido de cálcio (Dycal, Dentsply); e dois definitivos, o cimento de fosfato de zinco (SSWhite) e o cimento resinoso (Relyx Unicem, 3M Espe). Material e métodos: foram confeccionados 30 corpos-de-prova constituídos pelo cilindro cimentável e coping metálico, divididos em três grupos (n=10) que receberam os diferentes agentes de cimentação. As amostras foram submetidas à termociclagem, em seguida hemisseccionadas e então avaliadas em microscópio eletrônico de varredura (MEV) com aumento de 420 vezes. Resultados: não foram observadas diferenças signifi cativas entre os valores de desajuste marginal vertical para os três cimentos, porém, para a desadaptação interna, a maior discrepância foi obtida pelo cimento de hidróxido de cálcio. Conclusão: o cimento provisório apresentou comportamento similar aos cimentos definitivos em relação à adaptação marginal, porém, foi menos eficiente no desajuste interno dos copings.


Objective: to evaluate the vertical and internal marginal leakage between the cement cylinder and the metallic coping using three different types of cements, one temporary cement, calcium hydroxide cement (Dycal, Dentsply) and two definitive cements, zinc phosphate cement (SSWhite) and resin cement (Relyx Unicem, 3M Espe). Material and methods: 30 specimens were prepared, constituted by the cement cylinder and the metallic coping, divided into 3 groups (n=10) which received different luting agents. The samples were submitted to thermocycling and then hemisected. These were then evaluated in a scanning electron microscope (SEM) with 420 x magnification. Results: there were no statistically signifi cant differences between the vertical misfit values for the three cements, however, for the internal fit, the largest discrepancy was obtained by the calcium hydroxide cement. Conclusion: the temporary cement showed similar behavior to definitive cements on the marginal adaptation, but its internal misfit was higher.


Subject(s)
Humans , Calcium Hydroxide , Dental Cements , Dental Implants , Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported , Resin Cements
4.
PróteseNews ; 3(4): 444-454, out.-dez. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-837412

ABSTRACT

Este trabalho teve como meta ilustrar um caso clínico que oferece noções da sequência clínica e alguns passos explicativos das fases laboratoriais para a aplicação do processo de eletroerosão em infraestruturas de próteses protocolo fresadas pelo sistema CAD/CAM, colaborando com a literatura e clínicos interessados, dando um diagnóstico da situação atual do tema. O trabalho executado atendeu às expectativas de estética da paciente e aos anseios profi ssionais em relação à passividade clínica obtida pela prótese.


This article aimed to illustrate a case that off ers notions of the clinical and laboratorial steps of the spark erosion technique in implant-supported metallic CAD/CAM milled frameworks and thus contribute to literature and clinicians interested in that, providing a diagnosis of the current status of the subject. The work performed met the expectations of the patient's aesthetic desires and professionals wishes towards the clinical passivity in the prosthesis.


Subject(s)
Humans , Female , Middle Aged , Computer-Aided Design , Dental Implants , Dental Prosthesis, Implant-Supported , Mouth Rehabilitation
5.
ImplantNewsPerio ; 1(2): 271-275, fev.-mar. 2016.
Article in Portuguese | LILACS, BBO | ID: biblio-847354

ABSTRACT

Objetivos: avaliar se a união entre implantes e/ou a presença de gengiva artifi cial infl uencia no sangramento a sondagem dos tecidos peri-implantares. Material e métodos: foram incluídos pacientes tratados com implantes de titânio (Implacil De Bortoli, São Paulo, Brasil), instalados no período de 1998 a 2012, na Universidade de São Paulo (USP). Os implantes foram examinados para avaliação do sangramento a sondagem, sendo divididos de acordo com o tipo de prótese: unitárias (n=167), parciais (n=522) e totais (n=227); e de acordo com a ausência (n=674) ou presença (n=242) de gengiva artifi cial. O teste estatístico com equação de estimativa generalizada foi usado para testar possíveis associações. Resultados: foram examinados 183 pacientes reabilitados com 916 implantes em função, pelo menos por um ano. Ao menos um ponto de sangramento a sondagem foi detectado em 85 (50,9%), 304 (58,2%) e 129 (56,8%) implantes das próteses unitárias, parciais e totais, respectivamente. Em relação à gengiva artificial, 378 (56,1%) dos implantes sem e 140 (57,9%) dos implantes com esta característica apresentaram sangramento a sondagem. Não foram verificadas diferenças significativas entre os grupos. Conclusão: a união dos implantes ou a presença de gengiva artificial não foram associadas com os resultados de sangramento a sondagem nos implantes em função.


Objective: to evaluate whether the prosthesis type (single, partial, complete) and/or the presence of artifi cial gingiva can influence on bleeding on probing of peri-implant tissues. Material and methods: patients treated with titanium dental implants (Implacil De Bortoli, São Paulo, Brazil) between 1998 to 2012 at the University of Sao Paulo (USP) were included in this study. The implants were divided according the following prosthodontic types: single (n=167), partial (n=522), and complete (n=277), and also regarding the presence (n=674) or absence (n=242) or artificial gingiva. The generalized estimating equation test was used to verify possible associations. Results: 183 patients and 916 implants at least 1 year in function were screened. At least one bleeding point was detected in 85 (50.9%), 304 (58.2%), and 129 (56.8%) implants for single, partial, and complete prostheses, respectively. 378 (56.1%) and 140 (57.9%) implant from groups without and with artificial gingiva presented bleeding on probing. No significant differences were identified among groups. Conclusion: the prosthesis design and/or artifi cial gingiva were not associated to bleeding on probing for dental implants in function.


Subject(s)
Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Dental Implants/statistics & numerical data , Dental Prosthesis, Implant-Supported , Gingiva , Peri-Implantitis/complications , Periodontal Diseases
6.
Bauru; s.n; 2015. 192 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867424

ABSTRACT

O sucesso a longo prazo dos implantes tem como fatores críticos a incidência e a transferência de estresses mecânicos sobre a prótese, intermediários, implantes e destes para o tecido ósseo adjacente, devendo cada parte deste sistema ser submetido somente a forças às quais estão aptos a receber. A proposta deste trabalho foi avaliar a deformação gerada nos intermediários e na região óssea peri-implantar diante da aplicação de cargas funcionais e parafuncionais em prótese parcial fixa de três elementos parafusadas sobre dois implantes. Para este trabalho, foi utilizado um modelo experimental homogêneo à base de poliuretano, simulando o tecido ósseo, com dois implantes do tipo hexágono externo paralelos que receberam intermediários do tipo multi-unit. Na superfície de cada intermediário foram instalados três sensores (strain gauges), capazes de medir a microdeformação dispostos de maneira eqüidistante entre si. Na região óssea simulada, foram instalados quatro sensores para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. A aplicação da carga estática de 300N foi realizada em uma máquina de ensaios universais. As leituras foram realizadas em quatorze momentos para todos os corpos de prova, variando o direcionamento da carga (axial e inclinada à 30 graus) e simulando ainda sete diferentes pontos de aplicação de carga (1- pilar mesial, 2 - pôntico, 3- pilar distal, 4- simultaneamente no pilar mesial, pontico e pilar distal, 5- no pilar mesial e distal, sem contato no pôntico, 6- no pilar mesial e no pôntico, 7- no pilar distal e no pôntico). Os resultados mostraram que a direção da carga interferiu na magnitude e distribuição da microdeformação, de forma que, no osso simulado, os valores encontrados na carga axial se encontraram dentro da tolerância fisiológica independente do local de aplicação de carga. Observou-se uma distribuição mais uniforme quando a carga foi aplicada simultaneamente nos pilres mesial...


Long-term success with implants has some critical factors such as incidence and transmission of mechanical stress to the prosthesis, abutments, and implants to the adjacent bone tissue. Each part of the system should be subjected to loads under its strength limit. The purpose of the present study was to evaluate abutment and peri-implant bone tissue strains during functional and parafunctional loads application in a three-unit screw-retained fixed prosthesis supported by two implants. In order to simulate the bone tissue, an experimental model made of homogeneous polyurethane was used wherein two external hexagon implants were placed parallel to each other, provided with multi-unit abutments. On the surface of each abutment three sensors (strain gauges) were positioned equidistant to each other to measure microstrains. The simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The tests were performed applying a 300N static load on a universal testing machine. The readings were made at fourteen moments for each specimen, changing load direction (axial and 30 degrees oblique) and also simulating seven different points of load application (1- mesial abutment, 2- pontic, 3- distal abutment, 4- simultaneously on the mesial abutment, pontic and distal abutment, 5- mesial and distal abutment (no pontic contact), 6- mesial abumtent and pontic, 7- distal abutment and pontic. The results showed that the load direction significantly influenced the magnitude and distribution of microstrains, so that for the simulated bone, the values found during axial load were within the physiological threshold independent of the point of load application; however, a more uniform distribution was observed when force was applied simultaneously on the mesial abutment, pontic and distal abutment. Furthermore, microstrain values above the tolerance limits were observed during oblique load, and for this...


Subject(s)
/methods , Dental Prosthesis, Implant-Supported/methods , Biomechanical Phenomena , Bone Screws , Dental Stress Analysis , Mandible , Maxilla , Reference Values , Tensile Strength , Weight-Bearing
7.
Bauru; s.n; 2015. 192 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-794219

ABSTRACT

O sucesso a longo prazo dos implantes tem como fatores críticos a incidência e a transferência de estresses mecânicos sobre a prótese, intermediários, implantes e destes para o tecido ósseo adjacente, devendo cada parte deste sistema ser submetido somente a forças às quais estão aptos a receber. A proposta deste trabalho foi avaliar a deformação gerada nos intermediários e na região óssea peri-implantar diante da aplicação de cargas funcionais e parafuncionais em prótese parcial fixa de três elementos parafusadas sobre dois implantes. Para este trabalho, foi utilizado um modelo experimental homogêneo à base de poliuretano, simulando o tecido ósseo, com dois implantes do tipo hexágono externo paralelos que receberam intermediários do tipo multi-unit. Na superfície de cada intermediário foram instalados três sensores (strain gauges), capazes de medir a microdeformação dispostos de maneira eqüidistante entre si. Na região óssea simulada, foram instalados quatro sensores para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. A aplicação da carga estática de 300N foi realizada em uma máquina de ensaios universais. As leituras foram realizadas em quatorze momentos para todos os corpos de prova, variando o direcionamento da carga (axial e inclinada à 30 graus) e simulando ainda sete diferentes pontos de aplicação de carga (1- pilar mesial, 2 - pôntico, 3- pilar distal, 4- simultaneamente no pilar mesial, pontico e pilar distal, 5- no pilar mesial e distal, sem contato no pôntico, 6- no pilar mesial e no pôntico, 7- no pilar distal e no pôntico). Os resultados mostraram que a direção da carga interferiu na magnitude e distribuição da microdeformação, de forma que, no osso simulado, os valores encontrados na carga axial se encontraram dentro da tolerância fisiológica independente do local de aplicação de carga. Observou-se uma distribuição mais uniforme quando a carga foi aplicada simultaneamente nos pilres mesial...


Long-term success with implants has some critical factors such as incidence and transmission of mechanical stress to the prosthesis, abutments, and implants to the adjacent bone tissue. Each part of the system should be subjected to loads under its strength limit. The purpose of the present study was to evaluate abutment and peri-implant bone tissue strains during functional and parafunctional loads application in a three-unit screw-retained fixed prosthesis supported by two implants. In order to simulate the bone tissue, an experimental model made of homogeneous polyurethane was used wherein two external hexagon implants were placed parallel to each other, provided with multi-unit abutments. On the surface of each abutment three sensors (strain gauges) were positioned equidistant to each other to measure microstrains. The simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The tests were performed applying a 300N static load on a universal testing machine. The readings were made at fourteen moments for each specimen, changing load direction (axial and 30 degrees oblique) and also simulating seven different points of load application (1- mesial abutment, 2- pontic, 3- distal abutment, 4- simultaneously on the mesial abutment, pontic and distal abutment, 5- mesial and distal abutment (no pontic contact), 6- mesial abumtent and pontic, 7- distal abutment and pontic. The results showed that the load direction significantly influenced the magnitude and distribution of microstrains, so that for the simulated bone, the values found during axial load were within the physiological threshold independent of the point of load application; however, a more uniform distribution was observed when force was applied simultaneously on the mesial abutment, pontic and distal abutment. Furthermore, microstrain values above the tolerance limits were observed during oblique load, and for this...


Subject(s)
/methods , Dental Prosthesis, Implant-Supported/methods , Biomechanical Phenomena , Bone Screws , Dental Stress Analysis , Mandible , Maxilla , Reference Values , Tensile Strength , Weight-Bearing
8.
Braz. dent. j ; 25(6): 554-560, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-732259

ABSTRACT

The aim of this study was to assess, by the three-dimensional finite element method, the influence of crown-to-implant ratio and parafunctional occlusal loading on stress distribution in single external hexagon implant-supported prosthesis. Computer-aided design software was used to confection three models. Each model was composed of a block bone and an external hexagon implant (5x10.0 mm) with screw-retained implant prostheses, varying the height crown: 10, 12.5 and 15 mm. Finite element analysis software was used to generate the finite element mesh and to establish the loading and boundary conditions. Normal (200 N axial and 100 N oblique load) and parafunctional forces (1,000 N axial and 500 N oblique load) were applied. The results were visualized by von Mises and maximum principal stress. In comparison with the normal occlusal force, the parafunctional occlusal force induced an increase in stress concentration and magnitude on implant (platform and first threads) and screw (neck). The cortical bone showed the highest tensile stress under parafunctional force (oblique load). The stress concentration increased as the crown height increased. It was concluded that: increasing the C/I increased stress concentration in both implant components and cortical bone; parafunctional loading increased between 4-5 times the value of stresses in bone tissue compared with functional loading; the type of loading variation factor is more influential than the crown-to-implant factor.


O objetivo deste estudo foi avaliar, através do método dos elementos finitos tridimensionais, a influência do carregamento oclusal parafuncional e da altura da coroa na distribuição das tensões em próteses unitárias implantossuportadas de hexágono externo. Foram confeccionados três modelos com o auxílio de programas de desenho assistido. Cada modelo foi composto por um bloco ósseo da região molar mandibular, por um implante de tipo hexágono externo (5x10,0 mm) e por coroa com diferentes alturas: 10, 12,5 e 15 mm. Os modelos foram exportados para o programa de elementos finitos NEiNastran 9.0, para geração das malhas e estabelecer as condições de contorno. Aplicou-se uma carga funcional (200 N axial e 100 N oblíqua), bem como uma carga parafuncional (1.000 N axial e 500 N oblíqua). Os resultados foram visualizados por meio de mapas de Tensão de von Mises e mapas de Tensão Máxima Principal. O carregamento parafuncional induziu um aumento da área de distribuição e da magnitude das tensões no implante (plataforma e primeiras roscas) e parafuso (pescoço) em comparação com o carregamento funcional. A cortical óssea apresentou maiores áreas de tensão por tração sob carregamento parafuncional oblíquo. A concentração de tensões aumentou à medida que aumentou a altura da coroa. O aumento da altura da coroa induziu um aumento na concentração de tensões, tanto nos componentes do implante, quanto na cortical óssea; o carregamento parafuncional induziu um aumento entre 4-5 vezes da magnitude das tensões no tecido ósseo; o tipo de carregamento apresenta-se como um fator de variação mais influente do que a proporção coroa/implante.


Subject(s)
Animals , Male , Rats , Flavonoids/pharmacology , Hemodynamics/drug effects , Quercetin/pharmacology , /antagonists & inhibitors , Blood Pressure/drug effects , Dioxolanes/pharmacology , Heart Rate/drug effects , Infusions, Intravenous , Injections, Intravenous , Parasympatholytics , Quercetin/analogs & derivatives , Rats, Inbred Strains , Time Factors
9.
ImplantNews ; 11(6): 763-768, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-743135

ABSTRACT

O objetivo deste estudo foi avaliar a transmissão da carga mastigatória ao osso de suporte em próteses implantossuportadas em função do cantiléver, variando o tipo de pilar (Micro-Unite Ucla). A partir de dois modelos de poliuretano (norma ASTM F –1839), foram inseridos três implantes em cada, a uma distância de 8 mm, que conformaram os grupos: 1) implantes de hexágono externo e pilares Micro-Unit; 2) implantes de hexágono externo e pilares Ucla. Foram confeccionadas estruturas protéticas em resina acrílica ativada quimicamente sob cilindros com base de Co-Cr, que foram fundidas pela técnica convencional à brasagem. Foram fixados extensômetros no poliuretano entre os implantes e um na distal do implante mais próximo ao cantiléver. Em uma máquina de ensaio universal (2000RK – Kratos, São Paulo, Brasil), foi realizada a aplicação da carga de 150 N. A carga foi aplicada entre os implantes e no cantiléver nos intervalos de 5, 10, 15, 20 e 25 mm. Os dados obtidos foram analisados estatisticamente para cada extensômetro e levando em consideração a extensão do cantiléver. Quanto maior a extensão do cantiléver, maior a deformação superficial do osso ao redor do implante mais distal. A utilização do componente tipo Micro-Unit apresentou valores de deformação inferiores em relação ao Ucla.


Objectives: to evaluate transmission of masticatory loads according to different prosthetic implant abutment and cantilever lengths. Material and methods: two polyurethane models (ASTM F-1839) received 3 external hex dental implants 8 mm each apart divided into two groups: 1) Micro-Unit and, 2) Ucla. Metallic frameworks were prepared using acrylic resin and cast over CoCr prosthetic cylinders. Strain gauges were attached at the polyurethane-abutment interface and at the distal part of the implant near the cantilever. After, a 150 N load (2000 RK, Kratos, São Paulo, Brazil) was applied at 15, 20, and 25 mm from the most distal implant. Statistical analysis considered abutment type and cantilever lengths. Results: longer cantilevers generate more deformation in the distal implant. Deformation values at Micro-Unit were lower than at Ucla abutment type.


Subject(s)
Bite Force , Dental Implants , Dental Prosthesis, Implant-Supported
10.
ImplantNews ; 11(1): 61-65, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-730045

ABSTRACT

Objetivos: este trabalho avaliou a adesão de microrganismos em mangueiras com nanotecnologia de prata para prevenção da contaminação em procedimentos aplicáveis à prótese sobreimplantes. Material e métodos: após 24 meses de uso clínico, 20 segmentos de mangueiras foram divididos em dois grupos iguais (com e sem B-Safe, dez elementos cada) e colocados em tubos de ensaio contendo 10 mL de caldo BHI, incubados a 37ºC em condições de aerobiose. Depois, foram realizadas diluições decimais seriadas de alíquotas de 50,0 µL em dois meios de cultura: ágar sangue e ágar-sabourad dextrose, bem como a incubação das placas de Petri a 37ºC por 24/48h em aerobiose. Diferenças nas contagens de microrganismos (UFC/mL) foram analisadas pelos testes Anova e Tukey (p ≤ 0,05). Resultados: houve turvação do meio de cultura em todos os tubos do grupo controle, sendo que a contagem das colônias formadas revelou um alto nível de contaminação em mangueiras convencionais (ágar-sangue: 2.025 UFC/mL e agar-dextrose: 483 UFC/mL). Os tubos do grupo controle não apresentaram turvação, tampouco unidades formadoras de colônias. Conclusão: a tecnologia da nanocobertura de prata incorporada à linha de água do consultório pode impedir a contaminação durante os procedimentos clínicos para confecção das próteses sobreimplantes.


Objectives: this study evaluated the adherence of microorganisms to tubes with silver nanotechnology to prevent contamination in implant-supported associated procedures. Material and methods: after 24 months of clinical use, twenty tubes segments were divided into two equal groups (with and without B-Safe, ten elements each) and were placed in test tubes containing 10.0 mL of BHI broth, which were incubated at 37°C in aerobic condition. After this time, serial decimal dilutions of 50.0 µL aliquots were made on two culture media: blood agar and sabourad dextrose agar, followed by the incubation of the Petri dishes at 37ºC in aerobiosis. Differences in microorganism counts (CFU/mL) were analyzed by Anova and Tukey (p ≤ 0.05). Results: there was turbidity of the culture medium in all test tubes of control group, and the counting of colonies formed revealed a high level of contamination in conventional tubes (blood agar: 2.025 CFU/mL and dextrose agar: 483 CFU/mL). The tubes of control group showed no turbidity or colonies forming units. Conclusion: the silver nanocoating incorporated into the waterline of the dental office can prevent contamination during clinical procedures for implant-supported prostheses


Subject(s)
Biofilms , Nanotechnology
11.
ImplantNews ; 11(2): 246-253, 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-730841

ABSTRACT

A reabilitação provisória rígida implantossuportada tem sido reconhecida por ter um impacto significativo sobre a resposta do tecido peri-implantar em carga imediata, uma vez que reduz a tensão mecânica exercida sobre cada implante. Um protocolo de sucesso para a carga imediata com implantes múltiplos depende de uma fixação adequada e da ausência de mobilidade dos implantes para evitar o risco de micromovimentos em relação ao osso circundante. O objetivo deste artigo foi demonstrar um conceito de prótese implantossuportada com uma esplintagem rígida rápida de vários implantes cone-morse com carregamento imediato para o mesmo dia da cirurgia, com uma reabilitação provisória reforçada por uma liga metálica, usando uma técnica de soldagem dos pilares de implantes diretamente na cavidade bucal com uma barra de titânio pré-fabricada.


The rigid implant-supported provisional rehabilitation has been recognized to have a significant impact on the peri-implant tissue response in immediate implant loading since it reduces the mechanical stress exerted on each implant. A successful protocol for immediate loading of multiple implants depends on an adequate fixation and immobility of the implants to prevent the risk of micromovements in relation to the surrounding bone. The objective of this article was show a implant-supported rehabilitation concept with a fast rigid splinting of multiple tapered connection implants for same-day immediate loading with metal-reinforced provisional restorations using a technique of welding implant abutments with a prefabricated titanium bar directly in the oral cavity.


Subject(s)
Humans , Dental Soldering , Immediate Dental Implant Loading
12.
Rev. Salusvita (Online) ; 32(1)2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-698387

ABSTRACT

Introduction: the rehabilitation of edentulous mandible by four interforaminal implants with the distal ones inserted tilted in order to avoid proximity with the mentual foramen as well as improving prosthesis support have been argued as an adequate design for implant supported fixed prosthesis. Objective: the aim of this study was to compare tissue response around immediately loaded mandibular dental implants with two different prosthetic connections. Methods: a total of 48 implants were inserted in the anterior region of the mandible of 12 edentulous patients following a randomized split-mouth design. Morse Taper and External Hexagon implants were equally divided into each patient. Distal implants were tilted and central implants axially positioned in relation to the alveolar crest. Standardized intraoral radiographs were taken immediately after implant placement and after 6 months. Periodontal parameters (probing depth and keratinized tissue width and height) were recorded at the same times. Wilcoxon test was used. Results and Discussion: It was observed stability of the gingival margin and decrease in probing depth around Morse taper implants and increase in external hexagon implants. There was marginal bone increase in the mesial face (0.27 mm) and decrease at the distal face (-0.87 mm) of Morse taper and at both proximal faces of external hexagonimplants (-1.06 mm and -0.80 mm, respectively). Morse taper tilted implants showed maintenance of bone height (0.03 mm and-0.02mm, mesial and distal) while external hexagon implants showed resorption (-1.82 mm and -0.75 mm, mesial and distal). Axially positioned implants showed bone loss, either Morse taper (-0.72 and-0.67mm, mesial and distal) or external hexagon (-0.69 and -0.83mm).


Introdução: Tem sido sugerido que a reabilitação de mandíbulas edêntulas por meio de quatro implantes interforaminais, sendo os implantes distais instalados inclinados com o objetivo de evitar proximidade com o foramen mentual assim como melhorar o suporte da prótese, é um desenho adequado para próteses fixas implantossuportadas. Objetivo: o objetivo deste estudo foi comparar a resposta tecidual ao redor de implantes dentários mandibulares com dois diferentes tipos de conexões. Métodos: quarenta e oito implantes foram instalados na região anterior da mandíbula de 12 pacientes edêntulos segundo desenho experimental em boca dividida. Implantes cone Morse (CM) e hexágono externo (HE) foram igualmente distribuídos entre os pacientes. Os implantes distais foram instalados inclinados e os centrais axiais à crista óssea alveolar. Radiografias intrabucais padronizadas foram tomadas após a instalação dos implantes e após 6 meses. Parâmetros periodontais (profundidade de sondagem e altura e espessura de tecido queratinizado) foram registrados nos mesmos tempos. Resultados e discussão: observou-se estabilidade da margem gengival ao redor dos implantes CM e aumento nos implantes HE. Houve ganho ósseo em altura na face mesial (0,27 mm) e diminuição na face distal (-0,87 mm) dos implantes CM e em ambas as faces dos implantes HE (-1,06 mm e -0,80 mm, respectivamente). Implantes CM inclinados mostraram manutenção da altura óssea (0,03 m e -0,02mm, mesial e distal) enquanto os HE mostraram perda em altura (-1,82 mm e -0,75 mm, mesial e distal). Implantes axiais, CM (-0,72 e -0,67mm, mesial e distal) e HE (-0,69 e -0,83 mm) mostraram perda óssea.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Immediate Dental Implant Loading , Mouth Rehabilitation , Mandibular Reconstruction
13.
ImplantNews ; 10(6a): 185-194, 2013. tab, ilus
Article in Portuguese | LILACS | ID: lil-761243

ABSTRACT

A carga imediata de implantes no maxilar inferior está certificada por numerosos estudos demonstrando previsibilidade e taxa de êxito similares ou ainda maiores que na carga convencional. O propósito deste artigo foi reportar uma técnica protocolar de colocação de quatro a seis implantes com tratamento de superfície no maxilar inferior, mediante a utilização de um guia de transferência translúcido (GTT). A utilização deste dispositivo simplifica a localização dos implantes, sua transferência e a realização de registros estéticos e intermaxilares. A prótese parafusada é feita no laboratório e os implantes são carregados dentro de 72 horas. No presente artigo, descreveu-se as etapas pré-operatórias, cirúrgico protéticas, de elaboração da prótese, instalação e controles posteriores. Um total de 20 pacientes (111 implantes) foi tratado com este protocolo e controlado durante 18 meses (+/- três meses). A taxa de sobrevida dos implantes foi de 100% e das próteses foi de 95%...


Immediate implant loading in the lower jaw is supported by numerous studies demonstrating predictability and a success rate similar or even greater than conventional loading. The purpose of this article is to report a protocol technique placing four to six rough-surface implants in the mandible by means of a Translucent Transference Guide (T.T.G.). The use of this device simplifi es implant location, transferring, as well as aesthetic and intermaxillary records. A screwed prosthesis was made by the dental technician and the implants were loaded within 72 hours. This article describes the pre-surgical, surgical – prosthetic steps, prosthesis fabrication, delivery, and subsequent tests. A total of 20 patients (111 implants) were rehabilitated with this protocol and controlled for 18 months (+-3 months). The implant survival rate was 100% and the prosthetic success rate was 95%...


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Dental Implants , Immediate Dental Implant Loading , Mandible , Prostheses and Implants
14.
Dent. press implantol ; 6(1): 44-52, jan.-mar. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-700327

ABSTRACT

A Implantologia contemporânea, associada à prótese dentária, oferece alternativas diversificadas e muito bem fundamentadas para a resolução das mais variadas e críticas situações clínicas dentro da Odontologia. Essas situações tendem, naturalmente, a agrupar-se em classificações já amplamente estudadas e consagradas na literatura mundial, considerando-se, inclusive, a importância de resultados continuamente revelados por evidências científicas nesse amplo contexto. Dentro de limites muito bem definidos, é factível a indicação e possibilidade do reaproveitamento de implantes desfavoravelmente instalados, como ponto de partida para um outro planejamento protético. Realizar nova cirurgia para removê-los e, em seguida, instalar implantes em posições supostamente ideais, com os recursos que dispomos hoje, pode até ser mais lógico ou recomendável, mas nem sempre é tecnicamente possível sem que procedimentos mais complexos sejam requisitados, acarretando maior desconforto, morbidade e tempo total para finalização. Considerar todos os aspectos possíveis que possam envolver o paciente e o problema apresentado, aliado à coerência de uma conduta mais conservadora no planejamento de qualquer tratamento, faz com que o arrojo e a impetuosidade inerentes ao conhecimento das técnicas inovadoras ou de vanguarda, ainda que consagradas, mesclem-se providencialmente com a prudência e um calibrado comedimento no campo interpretativo dos tratamentos, resultando em grandes benefícios para os pacientes. Este artigo relata um caso que ilustra essa conjunção analítica de expectativas. Reúne ciência, consciência e experiência. Funde teoria e prática, aliadas ao bom senso e previsão de bom prognóstico.


The contemporary implantology associated with dental prosthesis, provide various and very well substantiated alternatives for the resolution of the most varied and critical situations in the dental clinics. These conditions, naturally tend to be grouped into classifications extensively investigated and already enshrined in the international literature, considering, inclusively the importance of the results continuously revealed by scientific evidence in this larger context. Within very well defined limits, it is feasible and possible the indication of reutilization of previously unfavorable installed implants, as the starting point for another prosthetic planning. Further surgery to remove them and later install implants into supposedly ideal positions considering the resources available today, it may even be more logical or recommended, but not always technically possible, without having complex and undesirable procedures being required, adding greater discomfort, morbidity, taking longer for finalization. Considering all possible aspects which may involve the patient and the problem presented, together with the consistency of a more conservative approach in the planning of any treatment, causes the boldness and impetuosity inherent to knowledge of the innovative and cutting-edge, yet consecrated techniques that merge providentially calibrated with prudence and restraint in the field of interpretive treatments, resulting in significant benefits for patients. This article reports a case that illustrates this combination of analytical expectations. It brings together science, consciousness and experience. It merges theory and practice, combined with the expectation of good sense and good prognosis.


Subject(s)
Humans , Female , Middle Aged , Dental Care , Dental Implantation , Dental Prosthesis, Implant-Supported , Mouth Rehabilitation , Dental Restoration Failure , Maxilla
15.
Araçatuba; s.n; 2011. 155 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-705168

ABSTRACT

Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...


Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...


Subject(s)
Dental Implantation , Dental Prosthesis, Implant-Supported , Post and Core Technique
16.
Araçatuba; s.n; 2011. 155 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-710786

ABSTRACT

Próteses implantossuportadas estão sujeitas a diversos tipos de falhas, sendo o afrouxamento do parafuso de retenção a complicação mais frequente, devido à perda da pré-carga inicial. A perda da pré-carga pode ser influenciada por fatores como incidência de cargas oclusais impróprias, diferentes tipos de conexões do sistema implante/prótese e desajustes entre a coroa e o implante. Sendo assim, este estudo teve como objetivo avaliar a manutenção da pré-carga de parafusos de retenção de titânio e a desadaptação vertical de coroas protéticas parafusadas, antes e após a ciclagem mecânica. Para isso, três tipos de conexões implante/pilar foram utilizados: implantes de conexão interna híbrida com pilar do tipo esteticone (grupo CIE); implantes de conexão externa com pilar o tipo esteticone (grupo CEE); e implantes de conexão externa com pilar UCLA (grupo CEU). Para cada grupo, foram confeccionadas 10 coroas metálicas fundidas em liga de CoCrMo para a composição final dos corpos-de-prova. Os parafusos de retenção protéticos receberam torque de 20N.cm nos grupos CIE e CEE e 30N.cm no grupo CEU, e, após três minutos, foi mensurado o valor de destorque inicial, com o auxílio de um torquímetro analógico. Após essa avaliação inicial, as coroas receberam novamente o torque recomendado e foram submetidas ao ensaio de ciclagem mecânica, com carga oblíqua (30°) de 130N ± 10N, a 2Hz de freqüência, totalizando 1x106 ciclos. Após a ciclagem, foi mensurado o destorque final. Além disso, antes e depois da ciclagem mecânica, foi realizada a verificação da adaptação vertical das coroas por meio de um estereomicroscópio, com as coroas parafusadas a um único implante e posicionadas em uma matriz de silicone a fim de padronizar seu posicionamento. Os dados obtidos foram tabulados e submetidos à análise de variância, teste exato de Fisher e correlação linear de Pearson (p<0,05). Todas as mensurações de destorque foram inferiores ao torque de inserção, tanto antes quanto após a ciclagem...


Implant-supported prostheses are prone to several types of fail, and the retaining screw loosening is the most frequent complication, due to the loss of its initial preload. Loss of preload may be caused by different factors such as the incidence of excessive occlusal loading, different types of implant/prosthesis connections systems and vertical misfit between crown and implant. Thus, the aim of this study was to evaluate the preload maintenance of titanium retaining screws and to measure the vertical misfit of implant-supported screwed crowns, before and after mechanical cycling. For this purpose, three types of implant/abutment systems were embedded in polyester resin: internal hybrid connection implants and Estheticone abutments (Group ICE); external connection implants with Estheticone abutments (Group ECE); and external connection implants with UCLA abutments (Group ECU). For each group, 10 metallic crowns were cast in CoCrMo alloy for the final compositions of the specimens. Retaining screws received insertion torque of 20 N.cm in groups ICE and ECE and 30N.cm in group ECU, and, after three minutes, the initial detorque was measured through an analogical torquemeter. After this initial evaluation, crowns were retightened and submitted to cyclic loading test, with an oblique loading (30°) of 130N ± 10N, at 2Hz of frequency, totalizing 1x106 cycles. After cycling, final detorque was measured. Moreover, before and after mechanical cycling, the vertical misfit of the crowns was measured through estereomicroscopy, with the crowns screwed to a single implant and positioned into a silicone matrix. The data obtained were tabulated and submitted to variance analysis, Fisher’s exact test and Pearson’s linear correlation (p<0,05). All detorque values were lower that the insertion torque, both before and after mechanical cycling. When groups were compared, there was no statistically significant difference before mechanical cycling. When groups were compared after...


Subject(s)
Dental Implantation , Dental Prosthesis, Implant-Supported , Post and Core Technique
17.
J. appl. oral sci ; 18(2): 178-185, Mar.-Apr. 2010. ilus
Article in English | LILACS | ID: lil-550410

ABSTRACT

OBJECTIVE: This study aimed to evaluate the bending moments, and compressive and tensile forces in implant-supported prostheses with three, four or five abutments. MATERIAL AND METHODS: Ten Pd-Ag frameworks were tested over two master models with: 1) parallel vertical implants, and 2) tilted distal implants. Strain gauges were fixed on the abutments of each master model to measure the deformation when a static load of 50 N was applied on the cantilever (15 mm). The deformation values were measured when the metallic frameworks were tested over three, four or five abutments, and transformed into force and bending moment values. Data were analyzed by ANOVA and Tukey's test for multiple comparisons at 5 percent level of significance. RESULTS: Abutment #1 (adjacent to the cantilever) had the highest values of force and sagittal bending moment for all tests with three, four or five abutments. Independently from the number of abutments, axial force in abutment #1 was higher in the vertical model than in the tilted model. Total moment was higher with three abutments than with four or five abutments. Independently from the inclination of implants, the mean force with four or five abutments was lower than that with three abutments. CONCLUSION: The results suggest that in the set-ups with four or five abutments tilted distal implants reduced axial force and did not increase bending moments.


Subject(s)
Humans , Dental Abutments , Dental Implants , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Analysis of Variance , Biomechanical Phenomena , Compressive Strength , Dental Implantation, Endosseous , Models, Dental , Dental Stress Analysis , Elasticity , Models, Structural , Pliability , Statistics, Nonparametric , Tensile Strength
18.
Rev. odonto ciênc ; 24(2): 145-150, abr.-jun. 2009. graf, ilus
Article in English | LILACS, BBO | ID: lil-518604

ABSTRACT

Purpose: To assess the magnitude and distribution of axial forces and bending moments in abutments as a function of cantilever length and inclination of implants. Methods: Ten metallic bars simulated frameworks of fixed implant-supported prosthesis over two master models with five implants: one with all implants straight and parallel (n=5) and one with the two distal implants tilted (n=5). Strain gauges were fixed on abutments to measure deformation when a 50N-load was applied on the cantilever at 10, 15, and 20mm-distance from the distal abutment. Deformation values were transformed into axial force and bending moment and analyzed by ANOVA and Tukey test (α = 5%). Results: Comparing 10mm- to 20mm-cantilever, there was an increase of approximately 50% for axial force and of 70% for saggital bending moment. On the abutment adjacent to the cantilever, the axial force in the inclined model was 70% lower than in the straight model, and bending moments did not vary. Conclusion: The results suggest that the inclination of distal implants does not have any deleterious biomechanical effect on abutments of the tested models and may reduce the cantilever effect on force magnitude.


Objetivo: Avaliar a magnitude e a distribuição de forças axiais e momentos fletores em pilares em função da extensão do cantilever e da inclinação dos implantes. Metodologia: Dez barras metálicas simularam infraestruturas de prótese fixa implantossuportada sobre dois modelos mestre com 5 implantes: um modelo com todos os implantes retos e paralelos (n=5) e um com os dois implantes distais inclinados (n=5). Extensômetros foram fixados nos pilares para medir sua deformação quando uma carga de 50N foi aplicada no cantilever a 10, 15 e 20 mm do implante distal. Os valores de deformação foram convertidos em força axial e momento fletor e analisados por ANOVA e teste de Tukey (α = 5%). Resultados: Comparando-se as distâncias de 10 e 20 mm, houve um aumento de aproximadamente 50% da força axial e de 70% do momento fletor sagital. No pilar adjacente ao cantilever, a força axial no modelo com implantes inclinados foi 70% menor que no modelo com implantes retos, e os momentos fletores não variaram. Conclusão: Os resultados sugerem que a inclinação dos implantes distais não promoveu nenhum efeito deletério sobre os pilares nos modelos testados e pode reduzir o efeito do cantilever na magnitude da força.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL